 |  | CGX-EGCP-03 |  
                            |  |  
                                | 
                                    Three phase AMF controller is a micro controller technology based, high performance product designed for control of emergency and stand-by power systems.  It integrates variety of functions such as starting or stopping of DG set upon failure or resumption of mains supply, protection to engine and generators and auto/manual controls with monitoring of electrical parameters.  It has built-in and user  friendly interface through 20X4 backlit LCD, mimic and twelve LED indications with operating keys.  The product has facilities to display 45programmalbe parameters.
CONTROLLER SPECIFICATION
DC Supply range	:	6 V to 36 V DC
Current Transformer input	:	0  to 5Amp.
VAC Input rating	:	40-300V / 50 HZ,
VAC  Max. Voltage range	:	600V
Solid state output	:	 500 mA Max.
Digital Inputs	:	 32V DC max with Ground
Display Accuracy	:	 +/-1% 
Overall Dimension, mm	:	96X192X80 (H XWXD)
Panel Cut Out, mm	:	92X184  (H X W)
Mouting		:	Panel , Flash
Operating Temperature	:	0 to 55-degree centigrade.
Storage Temperature 	:	-25 to 70
Relative Humidity at 40 °	:	0 to 95%
IMPORTANT PORT
Ø	45 Programmable Parameters
Ø	12 Digital Inputs, 11 Relay Outputs
Ø	12 individual LED indication for MIMIC
Ø	Programmable ETR / ETS mode.
Ø	Optical Isolation for Digital Inputs / Outputs
Ø Continuous monitoring and display of Mains and Generator 	Breakers
Ø Backlit LCD 20x4 lines	
Ø	Display and supervision of three phase mains voltages for 		UV / OV / 
	Unbalance,  single phasing and phase reversal
Ø	Measurement and display of electrical parameters of mains / DG 
Ø	Various fault monitoring like Start failure, Stop failure, over
	speed, Low Battery, low pressure and high canopy temp. and low 	fuel etc.
Ø	Date and time, with 99 fault data logger
Ø	With RS-232/485 Communication port.
Ø	Various programmable timers
Ø	Automatic periodic test.
Ø	Optional GSM / GPRS remote monitoring
PROTECTION
1) Emergency Stop	2) LLOP, 
3) Half Fuel, 	4) Low Fuel Inpu, 
5) High Coolant temp.	
6) DG Mains over voltage/under voltage 
7) DG Low/high Frequency/ Unbalance/ phase reversal etc.
8) Low Battery,  	9) Fail to start, 
10) Fail to stop, 	10)	Overload.
11) DG Contactor / Mains Contactor Feedback
MEASUREMENT
3 Phase DG Current, Power factor,  
Phase / Line Voltages of DG / Main
Active power-KW, KWH, for DG &Mains.
Engine Running Hours 
Battery Voltage
Engine Frequency (HZ) / Speed (RPM)
 |  
                                | Cologicx Systems pvt. Ltd. 
 